Valve Cv vs Kv Explained

Valve Cv vs Kv Explained: How to Read a Valve Datasheet

Drishty N.
November 27, 2026

Valve Cv and Kv Explained:

How to Read a Valve Datasheet Without Sizing Mistakes

Two quotations land on your desk for the same line. One lists the valve at Cv 100. The other says Kv 90. Which valve flows more?

Most people guess. The honest answer is that you cannot compare them until you convert one into the other, and the same trap shows up with pressure (bar, psi, kg/cm²) and torque (Nm, ft-lb). A unit slip is a quiet mistake. The valve arrives, fits the pipe, and then the line never delivers the flow it was meant to, or an actuator struggles to close it.

This guide covers the numbers that appear on almost every valve datasheet, how they relate, and how to check them before you place an order.

 

What Cv and Kv Actually Measure

Cv and Kv are both flow coefficients. They tell you how much liquid a valve passes at a fixed pressure drop when it is fully open. A higher number means the valve restricts the flow less.

  • Cv is the US definition: the flow of water at about 60°F (15.6°C), in US gallons per minute, that passes through the valve with a 1 psi pressure drop.
  • Kv is the metric definition: the flow of water in m³/h that passes through the valve with a 1 bar pressure drop.

 

They describe the same property in different units. The conversion is fixed:

 

To convert Formula Example
Cv to Kv Kv = Cv × 0.865 Cv 100 = Kv 86.5
Kv to Cv Cv = Kv × 1.156 Kv 90 = Cv 104

 

That means the Cv 100 valve in the opening example is actually the weaker one. At Kv 86.5 it falls short of the Kv 90 valve by almost 4 percent.

Quick rule: Cv always looks bigger than Kv for the same valve, by about 15.6 percent.

Never put a Cv figure into a formula that expects Kv, or the other way round.

 

 

A Worked Sizing Example

Suppose you need to pass 50 m³/h of clean water, and the system can afford a pressure drop of 0.3 bar across the valve.

For water, the required Kv is the flow divided by the square root of the pressure drop:

  • Kv required = 50 ÷ √0.3 = 50 ÷ 0.548 = about 91
  • In Cv terms: 91 × 1.156 = about 105

 

You can check this in imperial units as well. 50 m³/h is about 220 US gpm, and 0.3 bar is about 4.35 psi. Cv = 220 ÷ √4.35 = about 105. Same answer, which is what you want.

Now compare it with the datasheet. The valve you pick must have a full-open Kv at or above 91, and ideally you want it working at a partial opening so there is room to control the flow. For liquids heavier or lighter than water, divide the pressure drop by the specific gravity inside the square root.

Why this matters: a valve sized only by pipe diameter can be too restrictive for your flow, or much larger than needed.

Line size and valve size are not always the same thing. The datasheet Cv or Kv is what decides the pressure drop.

 

 

Pressure Units: bar, psi and kg/cm²

Indian plant drawings often use kg/cm². Imported equipment is usually in bar or psi. Valve standards use PN classes. Here is how they line up:

 

Unit Equals Notes
1 bar 14.5038 psi Common in pneumatics and European data
1 bar 1.01972 kg/cm² Close enough to treat as 1 in rough checks
1 kg/cm² 14.223 psi Still common in older Indian specifications
1 psi 0.0689 bar Used in US-origin datasheets and Cv
1 bar 100 kPa or 0.1 MPa SI units
1 bar about 10.2 m of water column Useful for pump head comparisons

 

A PN16 valve, for example, is a nominal 16 bar rating. That is about 16.3 kg/cm² or roughly 232 psi at the reference temperature. Remember that PN is a designation, and the pressure a valve can actually hold usually drops as the operating temperature climbs, so always check the pressure-temperature data for your service.

 

Torque Units: Nm, ft-lb and in-lb

Torque shows up when you add an actuator. The valve datasheet gives the torque needed to operate the valve, and the actuator catalogue gives the torque it can deliver. They have to be compared in the same unit.

  • 1 Nm = 0.7376 ft-lb
  • 1 Nm = 8.85 in-lb
  • 1 Nm = 0.102 kgf·m

 

So a valve needing 100 Nm needs an actuator delivering well above 73.76 ft-lb, not just equal to it. Actuator suppliers apply a safety margin on top of the published valve torque, because torque rises with pressure, media, seat wear and how long the valve sits closed. Ask for the torque at your actual working pressure, not the minimum figure.

 

Pocket Conversion Table

 

Quantity Conversion
Flow coefficient Kv = 0.865 × Cv   |   Cv = 1.156 × Kv
Flow rate 1 m³/h = 16.67 L/min = 4.403 US gpm
Flow rate 1 US gpm = 3.785 L/min
Pressure 1 bar = 14.5038 psi = 1.01972 kg/cm²
Pressure 1 kg/cm² = 14.223 psi = 0.981 bar
Torque 1 Nm = 0.7376 ft-lb = 8.85 in-lb

 

OSKO also has an Engineering Calculator on its website, under the Resource menu, with converters for length, pressure, temperature, power, volume, torque and Cv flow. It is a handy way to double-check a figure before it goes into an enquiry.

 

What to Send When You Ask for a Valve Recommendation

A short, complete enquiry saves days of back and forth. For a sizing recommendation, include:

  • Media, and its specific gravity if it is not water
  • Maximum, normal and minimum flow, with the unit written out (m³/h, L/min or gpm)
  • Allowable pressure drop across the valve
  • Operating pressure and temperature
  • Line size and flange standard
  • Whether the valve is manual or actuated, and the control signal if actuated

 

Four Unit Mistakes That Cost Money

 

  1. Comparing a Cv figure with a Kv figure.

A 15.6 percent gap is enough to move a valve from adequate to undersized. Convert first, then compare.

  1. Assuming kg/cm² and bar are the same.

They are close, about 2 percent apart, which is fine for a rough estimate. For a test pressure or a relief setting, use the exact value.

  1. Sizing by pipe diameter alone.

A DN100 valve is not a DN100 pipe. Two valves of the same size can have different Cv values depending on the disc or ball design.

  1. Matching actuator torque to the valve’s minimum figure.

Without a margin, the actuator may stall at high pressure or after a long idle period.

 

Frequently Asked Questions

 

Q: Is a higher Cv always better?

Not always. A higher Cv means lower pressure drop at full open, which is good for on/off service. For flow control, a valve that is far too large will work only in the first few degrees of opening, which makes control twitchy. Size for the duty, not for the biggest number.

Q: Does Cv change as the valve opens?

Yes. Datasheet values are normally for the fully open position. At partial openings the coefficient is lower, which is why control applications need the Cv curve for the valve type, not only the full-open figure.

Q: Does Cv apply to gas and steam?

The coefficient is a property of the valve, but the sizing equations are different for compressible fluids, and they depend on inlet pressure and temperature. Give the full operating conditions when your media is gas or steam.

Q: Can I use Cv for slurry or viscous fluids?

Cv is defined with water. Thick or particle-laden fluids need correction, so share the viscosity and solids content with your valve supplier.

Q: Which unit should I write in my enquiry?

Whichever you have, as long as you state it clearly. Write the unit next to every number. A figure without a unit is the most common cause of wrong quotations.

 

Get the Numbers Right Before the Order

Unit conversions are simple, but they are easy to skip when a project is moving fast. A two-minute check of Cv against Kv, bar against kg/cm², and Nm against ft-lb can save a valve from being returned or an actuator from being replaced.

OSKO Valves manufactures butterfly valves, ball valves and check valves at its facility in Rajkot, Gujarat. If you have your flow, pressure drop and media, send them across and our team will help you pick the right size and type.

 

Send us your requirement.

 

Share the media, flow rate, allowable pressure drop, operating pressure and temperature, and line size.

We will suggest a suitable valve and revert with the details.

 

Call / WhatsApp:  +91 8866226757  |  +91 8866221646

Email:  info@oskovalves.com

Website:  www.oskovalves.com

Address:  Plot No. 113, Gate No. 3, Khirasara GIDC, Khirasara, Rajkot – 360021, Gujarat, India